1. High quality material and first-class technology
2. Powerful function, continuously variable transmission
3. Regular appearance, small and beautiful
4. Convenient operation and intuitive digital display


Specification
|
VFD type |
HZ800SF |
HZ300A |
HZ800 |
|
Drive control mode |
VF/ Current closed loop Vector/velocity closed loop vector |
VF/ Current closed loop vector |
VF/ Current closed loop Vector/velocity closed loop vector |
|
Same power Starting torquecomparison |
★★★★★ |
★★★★ |
★★★★★ |
|
Torque control |
√ |
√ |
√ |
|
Shell color |
Brown |
Black |
Black |
|
Power range |
Three-phase 380V: 0.75 kw ~ 110 kw |
Single-phase 220V: 0.4 kw ~ 75 kw Three-phase 380V: 0.75 kw ~710 kw |
Single-phase 220V: 0.4 kw ~ 75 kw Three-phase 380V: 0.75 kw ~710 kw |
|
Operating keyboard |
Dual row display/LCD Shuttle potentiometer |
Single row display Adjustable potentiometer |
Single row display Adjustable potentiometer |
|
Synchronization rate volume |
★★★ |
★★★★ |
★★★★ |
|
Multifunction input Number of terminals |
8 |
8 |
8 |
|
Analog quantity Input quantity |
2 |
2 |
2 |
|
Analog quantity Output quantity |
2 |
2 |
2 |
|
Relay Output quantity |
2 |
2 |
2 |
|
485 communication |
√ |
√ |
√ |
|
Module/single tube |
Module |
Module |
Module |
|
An external expansion card is connected |
X |
X |
Support expansion card (PG/IO) |
Application
1: The hard start of the motor will cause serious impact on the power grid, but also the capacity of the power grid is too high, the large current and vibration generated during the start of the baffle and valve is greatly damaged, and the service life of the equipment and pipeline is extremely unfavorable. After the use of frequency conversion energy-saving device, the soft starting function of frequency converter will make the starting current start from zero, the maximum value will not exceed the rated current, reduce the impact on the power grid and the requirements of power supply capacity, prolong the service life of equipment and valves. The maintenance cost of the equipment is saved.
2: Theoretically speaking, frequency converter can be used in all mechanical equipment with motor, motor at start, the current will be 5-6 times higher than the rated, not only will affect the service life of the motor and consume more electricity. In the design of the system, there will be a certain margin in the motor selection, the speed of the motor is fixed, but in the actual use process, sometimes to run at a lower or higher speed, so it is very necessary to carry out conversion transformation. The inverter can realize the soft start of the motor and compensate the power factor.
Pictures
FAQ
Q: Do you supply pattern ? Is it free?
A: If the pattern is low value, we will grant the free pattern with freight collect. But for some excessive fee samples, we want to gather the pattern charge.
Q: What is your time period of payment?
A: 30% down charge earlier than producing and 70% stability charge earlier than shipping.
Hot Tags: VFD for 120v single phase motor, China VFD for 120v single phase motor manufacturers, suppliers, factory, 30KW VFD, 110v VFD Drive, Three Phase VFD, 5 5KW VFD, 660V 690V VFD, 45KW VFD