Products
VFD For 120v Single Phase Motor

VFD For 120v Single Phase Motor

1. High quality material and first-class technology
2. Powerful function, continuously variable transmission
3. Regular appearance, small and beautiful
4. Convenient operation and intuitive digital display

1. High quality material and first-class technology
2. Powerful function, continuously variable transmission
3. Regular appearance, small and beautiful
4. Convenient operation and intuitive digital display

 

product-500-500
2

 

Specification

 

VFD type

HZ800SF

HZ300A

HZ800

Drive control mode

VF/ Current closed loop

Vector/velocity closed loop vector

VF/ Current closed loop vector

VF/ Current closed loop

Vector/velocity closed loop vector

Same power

Starting torquecomparison

★★★★★

★★★★

★★★★★

Torque control

Shell color

Brown

Black

Black

Power range

Three-phase 380V:

0.75 kw ~ 110 kw

Single-phase 220V:

0.4 kw ~ 75 kw

Three-phase 380V:

0.75 kw ~710 kw

Single-phase 220V:

0.4 kw ~ 75 kw

Three-phase 380V:

0.75 kw ~710 kw

Operating keyboard

Dual row display/LCD

Shuttle potentiometer

Single row display

Adjustable potentiometer

Single row display

Adjustable potentiometer

Synchronization rate volume

★★★

★★★★

★★★★

Multifunction input

Number of terminals

8

8

8

Analog quantity

Input quantity

2

2

2

Analog quantity

Output quantity

2

2

2

Relay

Output quantity

2

2

2

485 communication

Module/single tube

Module

Module

Module

An external expansion card is connected

X

X

Support expansion card

(PG/IO)

 

Application

 

1: The hard start of the motor will cause serious impact on the power grid, but also the capacity of the power grid is too high, the large current and vibration generated during the start of the baffle and valve is greatly damaged, and the service life of the equipment and pipeline is extremely unfavorable. After the use of frequency conversion energy-saving device, the soft starting function of frequency converter will make the starting current start from zero, the maximum value will not exceed the rated current, reduce the impact on the power grid and the requirements of power supply capacity, prolong the service life of equipment and valves. The maintenance cost of the equipment is saved.

 

2: Theoretically speaking, frequency converter can be used in all mechanical equipment with motor, motor at start, the current will be 5-6 times higher than the rated, not only will affect the service life of the motor and consume more electricity. In the design of the system, there will be a certain margin in the motor selection, the speed of the motor is fixed, but in the actual use process, sometimes to run at a lower or higher speed, so it is very necessary to carry out conversion transformation. The inverter can realize the soft start of the motor and compensate the power factor.

 

Pictures

 

5U3A9496
5U3A9498
5U3A9542
5U3A9545
5U3A9554
5U3A9562

 

FAQ

 

Q: Do you supply pattern ? Is it free?

A: If the pattern is low value, we will grant the free pattern with freight collect. But for some excessive fee samples, we want to gather the pattern charge.

 

Q: What is your time period of payment?

A: 30% down charge earlier than producing and 70% stability charge earlier than shipping.

 

Hot Tags: VFD for 120v single phase motor, China VFD for 120v single phase motor manufacturers, suppliers, factory, 30KW VFD, 110v VFD Drive, Three Phase VFD, 5 5KW VFD, 660V 690V VFD, 45KW VFD

Send Inquiry