How to set the automatic restart parameters of a 30KW VFD?

Dec 15, 2025Leave a message

Hey there! As a supplier of 30KW VFDs (Variable Frequency Drives), I've gotten tons of questions about setting the automatic restart parameters. It's a crucial aspect, especially when you're relying on your VFD to keep your operations running smoothly. So, I'm gonna break it all down for you in this blog.

Why Automatic Restart Matters

Before we dive into how to set the parameters, let's talk about why automatic restart is so important. In industrial settings, power outages, momentary faults, or other disruptions can happen. When these occur, having your 30KW VFD set to automatically restart can save you a ton of time and hassle. Instead of having to manually restart the drive every time there's an issue, it can pick up right where it left off, minimizing downtime and keeping your production on track.

Understanding the Basics of Automatic Restart

The automatic restart function on a 30KW VFD allows the drive to resume operation after a fault or power interruption has been cleared. It's like having a safety net that kicks in when things go wrong. But to make it work effectively, you need to understand a few key parameters:

  1. Restart Delay Time: This is the amount of time the VFD waits after the fault or power interruption has been cleared before it attempts to restart. You can set this time based on your specific needs. For example, if you have a system that requires some time to stabilize after a disruption, you might want to set a longer delay.
  2. Restart Mode: There are usually a few different restart modes available, such as "flying start" and "start from zero." In a flying start, the VFD tries to sync with the existing motor speed and resume operation smoothly. This is great for applications where the motor might still be spinning when the restart occurs. On the other hand, starting from zero means the VFD will start the motor from a complete stop, which might be necessary in some cases.
  3. Restart Attempts: You can also set the number of restart attempts the VFD will make. If the first attempt fails, it will try again a certain number of times before giving up and indicating a fault. This can be useful if there's a temporary issue that might resolve itself with a few more tries.

Step-by-Step Guide to Setting Automatic Restart Parameters

Now that you have a basic understanding of the parameters, let's go through the steps to set them on your 30KW VFD. Keep in mind that the exact process might vary depending on the make and model of your drive, but the general principles are the same.

  1. Access the Parameter Menu: First, you need to access the parameter menu on your VFD. This is usually done by pressing the "Menu" or "Settings" button on the drive's control panel. You might need to enter a password or code to access certain settings, so make sure you have that handy.
  2. Locate the Automatic Restart Parameters: Once you're in the parameter menu, look for the section related to automatic restart. It might be labeled something like "Auto Restart" or "Restart Settings." Use the up and down arrows on the control panel to navigate to this section.
  3. Set the Restart Delay Time: In the automatic restart section, find the parameter for restart delay time. Use the numerical keypad or the up and down arrows to enter the desired delay time in seconds. For example, if you want the VFD to wait 10 seconds before attempting to restart, enter "10" in the appropriate field.
  4. Select the Restart Mode: Next, choose the restart mode that's right for your application. Select "Flying Start" or "Start from Zero" using the menu options. If you're not sure which mode to use, consult the VFD's manual or contact our support team for advice.
  5. Set the Number of Restart Attempts: Finally, set the number of restart attempts the VFD will make. This parameter is usually labeled something like "Restart Attempts" or "Retry Count." Enter the desired number of attempts using the numerical keypad. For example, if you want the VFD to try restarting 3 times before giving up, enter "3" in the field.
  6. Save the Settings: Once you've set all the parameters, make sure to save the settings by pressing the "Save" or "Enter" button on the control panel. You might need to confirm the changes by entering a password or code again.

Tips for Optimizing Automatic Restart Settings

  • Test the Settings: After you've set the automatic restart parameters, it's a good idea to test them to make sure they're working correctly. You can simulate a power outage or a fault by temporarily cutting the power to the VFD or triggering a fault condition. This will allow you to see how the drive responds and make any necessary adjustments.
  • Consider the Application: Different applications have different requirements when it comes to automatic restart. For example, in a critical process where any interruption can cause significant damage, you might want to set a longer restart delay time and a higher number of restart attempts. On the other hand, in a less critical application, you might be able to set a shorter delay and fewer attempts.
  • Keep an Eye on the VFD: Even with automatic restart enabled, it's important to monitor your VFD regularly to make sure it's operating properly. Check for any error messages or abnormal behavior, and address any issues as soon as possible.

Related Products

If you're interested in other VFD options, we also offer 22KW VFD and AC Control Drive. And for those working with 120v single phase motors, our VFD For 120v Single Phase Motor is a great choice.

Vfd For 120v Single Phase Motor22KW VFD

Contact Us for Purchase and Consultation

If you have any questions or need further assistance with setting the automatic restart parameters of your 30KW VFD, or if you're interested in purchasing a VFD, don't hesitate to reach out to us. We're here to help you find the right solution for your needs and ensure your operations run smoothly.